Description
Imaging characteristics
Type of X-ray source: Linear accelerator (LINAC) with dual energy
alternating impulses;
Energy: 6 / 4 MeV, alternating;
Penetration: 320 mm in steel;
Resolution of wire in air: 1mm;
Contrast sensitivity: 1% at 10% penetration; 1.5% at 50% penetration;
4% at 80% penetration;
Separation of materials: 4 grades;
Car
Chassis: 3-axle, gross weight 26 t. Computer control of speed, steering and braking
during the scanning process. Left hand or right hand drive. Various
manufacturers and models depending on specific local conditions;
Dimensions (LxWxH): 10 m x 2.5 m x 4 m (in transport version);
Environment: Compliance with Euro-6 standard;
Fuel consumption: Less than 15 l/h in sequential or sequential scan modes.
Radiation safety
Radiation level for the operator: natural level, without occupational exposure;
Radiation dose to the population outside the exclusion zone: less than 1 mSv/year according to IAEA, GSR3;
Radiation monitoring: individual monitoring for each operator;
Lack of people inside the exclusion zone
Operation features
Working principle: image transmission. Remote control via secure wireless
technology or through an Internet connection;
Scanning frame dimensions: 4.25 m wide x 5.1 m high; other sizes available upon request;
Deployment time: Maximum 15 minutes from arrival on site using automated process control;
Crew requirements: 1 operator/shift;
Vehicle inspection mode: single and sequential scanning mode for stationary vehicles,
through scanning mode for moving vehicles;
Throughput: 30 to 200 trucks/containers/hour depending on the length of each object being scanned and the scanning mode.
object and scan mode;
Scanning speed: in sequential or sequential scan modes: from 0.8 to 2.9 km/h;
in through scanning mode: 5 - 15 km/h;
Automatic recognition of: truck license plates (LPR cameras),
container codes (CCR chambers);
Warning lights and audible signal indicating "Emission activation status";
Safety features: External lighting for night work;
Digital video surveillance subsystem that allows the operator to control the scanning area;
Working temperature: from - 30 °C to + 55 °C;
(extreme kits available on request);
Relative humidity: 0-100%